METHODS FOR MEASURING APPLICATION RATE OF LIQUID MEMBRANE-FORMING CURING COMPOUNDS ON CONCRETE PAVEMENTS

Authors

  • Toy s. Poole

DOI:

https://doi.org/10.33593/iccp.v7i1.213

Keywords:

membrane-forming curing compounds, compounds, sampling coupons, visual estimation, reflectometer

Abstract

Several method of measuring application rates of liquid membrane-forming curing compounds were investigated. For non-pigmented compounds, a direct mass determination using sampling coupons appears to be the only plausible method. For white-pigmented compounds, reflectance was found to be a reasonably accurate, field applicable, method. Also, visual estimation of degree of whiteness was given a quantitative basis.

Downloads

Published

2001-09-09

How to Cite

[1]
Poole, T. s. 2001. METHODS FOR MEASURING APPLICATION RATE OF LIQUID MEMBRANE-FORMING CURING COMPOUNDS ON CONCRETE PAVEMENTS. Proceedings of the International Conference on Concrete Pavements. 7, 1 (Sep. 2001). DOI:https://doi.org/10.33593/iccp.v7i1.213.