Specification Synthesis and Recommendations for Repairing Uncontrolled Cracks that Occur During Concrete Pavement Construction
DOI:
https://doi.org/10.33593/iccp.v6i1.721Keywords:
specification synthesis, concrete pavement, construction, uncontrolled cracking, sawing windowAbstract
This paper, authored by Gerald F. Voigt from the American Concrete Pavement Association, discusses the phenomenon of uncontrolled cracking in newly constructed concrete pavements, despite the implementation of contraction joints designed to manage such cracking. It delves into the causes of these cracks, influenced by factors such as jointing methods, design features, environmental conditions, and timing of saw cuts. It identifies that optimal timing for sawing contraction joints, known as the "sawing window," is crucial for preventing these uncontrolled cracks but can be affected by weather, subbase conditions, concrete mixture characteristics, and saw blade selection.
The study reviews specifications from various state highway agencies regarding jointing and repairing cracked slabs, finding significant inconsistency. It suggests that new specifications should embrace the sawing window concept, providing clear guidance for handling uncontrolled cracking that might occur during or before sawing, including recommendations for when to use early-age saws and how to approach joint skipping. Additionally, it points out the necessity for a detailed damage repair clause in these specifications.
The paper concludes by emphasizing the importance of understanding the complex interplay of factors that can lead to uncontrolled cracking and the need for consistent, detailed guidelines that accommodate the variability in construction conditions to mitigate such issues effectively. (Abstract generated by AI tool ChatGPT 4)