EVALUATION OF STRENGTH TESTS AND ACCEPTANCE OF CONCRETE PAVEMENTS

Authors

  • Wilbur Greer

DOI:

https://doi.org/10.33593/iccp.v4i1.912

Keywords:

evaluation, concrete pavement, flexural strength, variations, compressive tensile strength, split tensile strength

Abstract

One of the most troublesome phases of a concrete pavement construction project can be the determination of whether the strength of the concrete meets the project specifications. This determination can be complicated by the fact that the flexural strength test is often the test specified for acceptance and there is often little or no understanding of the procedures and precision of the flexural strength test. The quick placement of large volumes of concrete for pavement construction projects means that a million dollars or more worth of concrete can be "on the ground" before the first acceptance test is ever performed. If questions arise regarding the validity of the acceptance tests, then a good understanding of the variations inherent in the flexural strength test are necessary for a proper evaluation of the acceptability of the concrete. The results of analyses to determine the statistical parameters for flexural strength test results for more than one million cubic yards of concrete pavement constructed at the Atlanta International Airport are presented in this paper. Parameters for within-test statistical variations are presented so that the quality of the testing agency personnel can be evaluated. Parameters for the between-test statistical variations are presented so that the quality of production by the contractor can be evaluated. The results of the analyses indicate that the within-test variations can approach the between-test variations and this greatly contributes to the confusion and misunderstandings. The analyses also show that two flexural strength test results from the same batch of concrete can be expected to vary by as much as 100 psi and not be considered suspect 95 percent of the time. The difference between the average flexural strengths of each of two batches of the same concrete mix in the laboratory can differ by as much as 75 psi and not be considered suspect 95 percent of the time. Procedures for adjusting the actual flexural strength test results upward based on additional thickness over the design thickness or downward based on deficient thickness from the design thickness are given. The use of compressive or split tensile strength test results in lieu of flexural strength test results for the acceptance testing for concrete pavement construction projects are also presented.

Downloads

Published

2025-01-04

How to Cite

[1]
Greer, W. 2025. EVALUATION OF STRENGTH TESTS AND ACCEPTANCE OF CONCRETE PAVEMENTS. Proceedings of the International Conference on Concrete Pavements. 4, 1 (Jan. 2025). DOI:https://doi.org/10.33593/iccp.v4i1.912.